UC2869XB Automatic Coil Transformer Inductance Tester India
UC2869XB(20Hz-200 kHz) UC2867XB (20 HZ-300 kHZ)
UC2866XB (20HZ -500 kHZ ) UC2878XB (20 HZ-1M HZ)
Comprehensive transformer tester is used to test multi parameters of transformer, coil and winding. Like Laps ratio, phase, inductance, capacitance, leakage inductance, quality factor, AC resistance, DC resistance, balance, pin short circuit etc.
Acquired from many years of marketing experiences and cumulative results, UC2869XB is the newest generation of Automatic Transformer Tester that not only retains the merits of old model, but also has many new functions including the combination of measurement unit and scan box to reduce the measurement errors.
It solves quality problems and performance as well as the human errors occurred on production line for the transformer industry today.
Brief Introduction
The most popular 7-inch 800×480 color TFT LCD display is used, it is more intuitive and more comfortable for users to read test results.
It is a transformer test system with high speed, high precision and high performance, which can meet the requirements of production line quality assurance, purchase inspection and laboratory measurement.
The UC2869XB automatic transformer test instrument is a precision test system, designed for transformer production line in quality control process, with high stability and high reliability.
With the enhanced capability in turn ratio measurement, they can solve the measuring problems of low coupling coefficient, turn ratio and number of turns with more precise measurement.
The UC2869XB automatic transformer test instrument 20Hz ~ 200kHz test frequency and scan tests items to cover low voltage test parameters for various transformers including Inductance (L), Leakage Inductance (Lk), Turn Ratio, DC Resistance (DCR), Impedance (Z), Quality Factor (Q), Pin Short test, Winding Phase and Balance Test.
UC2869XB Automatic Coil Transformer Inductance Tester India
Inductance measurement of Transformer, Relay, Solenoid Coils with LCR Meter
Working Video of the Transformer Tester
Performance Characteristics
■ 7 inch 16: 9 TFT LCD display, resolution: 800×480 RGB
■ All the test results are shown in one page without turning to other pages
■ It is more convenient for U disk to directly save the test results,
■ Maximum test frequency is 1MHZ , resolution is 10mHz.
■ Basic measurement accuracy is 0.05%,the ultra-fast test mode is increased (150 times / Sec)
■ Automatic level control ALC function for testing voltage or current
■ 30 Ω, 100 Ω, 10 /100, 10 /CC, four different signal sources & rsquo; output impedance.
■ Built-in comparator, 10 files sorting and file counting function
■ Internal 100 setting files are used to save or call, testing files of U disk are unlimitedly expanded to save or call.
■ Optional ±10V(±100mA) and 1 A internal DC bias source.
■ Software version of the instrument can be upgraded and updated by USB HOST.
■ U disk supports the file systems with FAT16, FAT32 format.
■ Standard RS232C、HANDLER、USB HOST, optional GPIB、LAN interface
Technical Specifications
Measurement function | ||||||
Test frequency | UC2869XB 20 Hz-200 kHz,10mHZ resolution UC2867XB 20 HZ – 300 kHZ, 10mHZ resolution UC2866XB 20 HZ – 500 kHZ, 10mHZ resolution UC2878XB 20 HZ – 1M HZ, 10mHZ resolution |
|||||
Transformer test parameter | Laps ratio, lap, phase, inductance, capacitance, leakage inductance, quality factor, AC resistance, DC resistance, balance, pin short circuit; LED test | |||||
Basic measurement accuracy | ||||||
LCRZ | 0.05% | |||||
DCR, Laps ratio | 0.1% | |||||
Equivalent circuit | Series, parallel | |||||
Math function | Absolute deviation, percentage deviation | |||||
Range method | Automatic, hold, manual selection | |||||
Trigger mode | Internal, manual, external, bus | |||||
Measurement speed(≥1kHz) | Ultra-fast speed :150 times/Sec, Fast speed: 90 times/Sec, medium speed: 12 times/Sec slow speed: 3 times/Sec |
|||||
Average times | 1—255 | |||||
Delay time | 0—60s, step :1ms | |||||
Correction function | Open circuit / short circuit / load | |||||
Test end configuration | Five ends | |||||
Display mode | Direct reading,Δ,Δ%,V/I(Measured voltage / current monitor) | |||||
Test signal | ||||||
Output impedance | 30 Ω, 100 Ω, 10 /100, 10 /CC | |||||
Test signal level | normal:5 mV-2 V accuracy:10%,1 mV step constant level:10 mV-1 V accuracy:5%,1 mV step |
|||||
DC bias source |
internal | 0V,1.5V,2V,accuracy:1% | ||||
optional | UC6802A:±10V(±100mA)DC bias current | |||||
UC6802B:0-1A DC bias current source | ||||||
Display range | ||||||
|Z|, R, X | 0.01m Ω — 99.9999 MΩ | |||||
DCR | 0.01 mΩ — 99.9999 MΩ | |||||
Laps ratio display range | 1:0.001-1000:1 | |||||
|Y|, G, B | 0.00001µS — 99.9999 S | |||||
C | 0.00001 pF — 9.9999 F | |||||
L | 0.00001 µH — 9999.99 H | |||||
D | 0.00001 — 9.9999 | |||||
Q | 0.00001 — 9999.9 | |||||
θ (DEG) | -179.999º — 179.999 º | |||||
θ (RAD) | -3.14159 — 3.14159 | |||||
Others | ||||||
Memory | Internal 100 groups storage, unlimited expansion for U disk | |||||
Interface | Standard RS232C, HANDLER, USB HOST, Optional GPIB, LAN interface |
|||||
UC2869XB Automatic Coil Transformer Inductance Tester India
Battery Internal Resistance Tester Distributor India
Introduction to Front Panel
- Buzzer window
- LCD : 800*480 colorful TFT LCD displays measurement results and conditions.
- Brand and model
- Soft keys : Six soft keys are used to select parameters. The corresponding function of each soft key has been displayed on its left (the right part of LCD). The function definition varies with different pages.
- [FILE] Press this key to enter into the file setup page.
- PASS indicator : LED indicator shows the test result has passed.
- [DISP] Press this key to enter into the display page of transformer scanning test.
- [SETUP] Press this key to enter into the setup page of transformer scanning test.
- FAIL indicator : LED indicator shows the test result has failed.
- [SYSTEM] Press this key to enter into the system setup page.
- Numerical keys : These keys are used to input data to the instrument. The key consists of numerical keys [0] to [9], decimal point [.] and [+/-] key.
- [ENTER] This key is used to end the input of data, and confirm and save the data displayed on the inputting line (the bottom line on LCD).
- [CAL] Execute the calibration operation. Press this key to execute OPEN/SHORT calibration.
- [ESC] ESCAPE key
- [←] BACKSPACE key is used delete the last numeric of the input value.
- [KEYLOCK] Press [KEYLOCK], it will be lighted, which means the function of current panel is locked. Press it again, it will be off, which means discharging the lock status.
If the password function is ON, it means correct password is necessary when discharging the key-lock, or the key cannot be unlocked.
- [DC BIAS] [DC BIAS] is used to permit or forbid the output of 0-100mA/10V DC bias source. Press this key, it will be lighted which means DC bias output is permitted. Press this key once more, it will be off which means DC bias output is prohibited. The key is useless in some pages where the DC BIAS cannot be added.
- [RESET] Press this key, when transformer auto scanning is cancelled, other operation cannot be executed on other pages.
- [TRIGGER] When the trigger mode is set to MAN mode, press this key to trigger the instrument.
- Transformer secondary test terminal (TURNS)
(+): Secondary (+) terminal
(-): Secondary (-) terminal
- Test terminals (UNKNOWN) 4-teminal test pair is used to connect 4-terminal test fixture or cable to measure DUT.
The 4 terminals are respectively as follows: Hcur, Hpot, Lpot and Lcur.
- CURSOR : Cursor key is used to select cursor between zone and zone on LCD display page. When cursor moves to some zone, the zone displays with reverse on LCD.
- Ground terminal : The ground terminal is connected with the case of instrument, which can be used to protect or shield the ground connection.
- [COPY] : Copy the currently displayed page to USB memory.
- POWER : Power switch
- USB HOST interface : Connect U flash disk so as to save or use a specified file.
Introduction to Rear Panel
- PHONE interface
- FOOT. C: Used to connect footswitch.
- RS232 interface : Series communication interface can realize the communication with PC.
- HANDLER interface : Handler interface is used to realize the sorting output of test results.
- IEEE-488 interface : The tester can communicate with PC through GPIB interface.
- Fan window : Heat elimination, maintaining the normal working temperature
- Fuse base : Being used to install power fuse, protect instrument.
- Power socket : Input AC power.
- Ground terminal : The ground terminal is connected with the case of instrument, which can be used to protect or shield the ground connection.
- 110V/220V Switch switch 110V/220V by changing the direction of core.
- SCANNER interface : Control the transformer scanning box through SCANNER interface.
- USB DEVICE interface : The tester can communicate with PC through the USB DEVICE interface.
- LAN interface : LAN interface is used to realize the control and the communication of network system.
UC2869XB Automatic Coil Transformer Inductance Tester India
12 Spindle Automatic Transformer Coil Winding Machine
Operation Instructions
<SYSTEM SETUP>
Press [System] to enter into the <SYSTEM SETUP> page, shown as below.
On this page, Basic system setup items are displayed, such as brightness, Theme, key sound, language, PASS word, file format, date, time.
<TEST SETUP>
Press [SYSTEM] ,and then TEST SETUP to enter into the <TEST SETUP> page shown as below.
On this page, basic test setup items are displayed, such as system function, beeper, pass beeper, fail beeper, bias source, handler mode, trigger edge, file info., auto trig mode, auto trig z.
<INTERFACE SETUP>
Press [SYSTEM] ,and then COMM SETUP to enter into the <INTERFACE SETUP> page shown as below.
On this page, basic interface setup items are displayed, such as bus mode.
Measurement Display
Transformer Auto Scanning Test
Introduction to scan test function
Automatic transformer test system consists of UC6801A/UC6801B transformer scanning box and UC2868.
It can test the following parameters: inductance (Lx), leakage inductance (Lk), quality factor (Q), turn (TURN), phase (PHASING), stray capacitance (Cx), DC impedance (DCR), AC impedance (ACR), impedance (Zx), inductance balance (Lx-BALANCE), DC impedance balance (DCR-BALANCE), short test (PIN-SHORT) and current bias (DCI-BIAS), etc.
UC2868 can realize the automatic conversion between transformer pins and fixture pins, automatic test time setup, multi-group primary winding test, multi-group leakage test, deviation compensation for test values, PASS and FAIL count for test result, save and load function for test parameter, repeat test for FAIL product, etc.
UC2868 can test 5 transformers at the same time.
Upper panel of Scanning Box
Introduction to the marking numbers:
1) Model of the fixture
2) Test fixture: This fixture is flexible and replaceable.
3) Cylinder: This is the main driving force for UC6801A; For UC6801B, the motive force is from a manual push rod.
4) RESET button: When pressing this button, all tests will be terminated and the instrument will recover to the original preparing test state.
5) GOOD indicator: If the specified test results meet the preset requirements, this indicator will light up, which indicates that the tested device is GOOD.
6) START button: It is used to control test. Press this button, the instrument will start test.
7) NG indicator: If one or two test results cannot meet to the preset requirements, this indicator will light up, which indicates that the tested device is NOT GOOD.
8) Speed control knob: The knob is used to adjust the driving speed of the cylinder. (none for UC6801B)
9) Inlet of the air pipe: This is the connection interface connecting with external air pipe. Note: It is recommended to install a water filtering device between the inlet and the inlet valve so as to improve the service life of the cylinder and the inlet valve. (This inlet is unavailable for UC6801B.)
10) Silencer: This is a silencer used for noise reduction and dust proof (only for UC6801A).
11) Control socket of air valve controller (electromagnetic valve): The switch for controlling UC6801A and the cylinder. The power is DC24V. There is no such a controller in UC6801B.
Lower panel of Scanning Box
Introduction to each number on the lower panel
- TEST LINE: inlet port of the test cable, UC6801L 6-terminal test box is connected to inner part of UC6801A/B through this line.
- CYLINDER: 24V DC voltage output terminal, providing the working voltage for UC6801A solenoid valve.
- FOOT. C: Used to connect footswitch.
- SCANNER: Signal control port. Use 36Pin control line to connect the scanning box with UC2868 through SCANNER port.
- HANDLER: HANDLER port. Refer to the next section for instruction of HANDLER port.
UC2869XB Automatic Coil Transformer Inductance Tester India
Relay Solenoid Coil Dip Soldering Machine Manufacturer India
Other Services we offered in Testing and Measuring in India:
Electronic Component Test
Used for test various types of electronic components
• Resistance Test
• Capacitance Test
• Inductance
Coil and Winding Product Test
Used for network transformer test, power transformer test, filter test, etc
• Transformer Tester
• Impulse Winding Tester
• DC Resistance Tester
• Filter Balance Tester
Wire Harness Test System
- New energy vehicle wire harness test
- Automobile, Train, Aerospace, Ship wire harness test
- Home appliances, Smart phone wire harness test
- Medical equipment wire harness test
- Other industry high voltage wire harness test
About Us
We are a high-tech enterprise engaged in sales and service of test instruments. At present, the company’s main products are: LCR meter, Hi-pot tester, automatic transformer tester, DC low resistance tester, impulse winding tester, wire harness test system.
After years of customer accumulation and product market recognition, we have become an influential brand in the industry.
“Quality first, customer satisfaction” is always our first goal. Quality is the life of an enterprise.
For this reason, we strive for excellence, optimize the design, improve the performance of products, and focus on the details of each product.
At the same time, we are also actively expanding overseas business. We gradually integrate the technology and experience accumulated for many years into the international competition system, to create a marketing system in Asia and European countries.